Ultrasonic Attenuation of High Concentration of Micron Particle Clouds
This paper presents the simulation and experiment about the attenuation characteristics of ultrasound in micron particle clouds.Firstly,several models that have been used in the suspension concentration measurement are analyzed.Then the numerical simulations are conducted to try to establish the relationship between the consciousness,particle size and the frequency.Finally,an experiment is conducted to verify whether the attenuation of ultrasound in micron particle clouds follows the simulations relusts.The results of numerical simulations and the experiment both show that the intensity of ultrasound has a positive correlation with the consciousness,but the relationship between the attenuation and particle size is still uncertain for lack of experimental data.At present,research is still in ongoing.
ultrasonic attenuation phase concentration micron particle
Guo Mingru Lou Wenzhong Liu Yankun Wang Fufu Ding Xuran
State Key Laboratory of Mechatronics Engineering and Control, Beijing Institute of Technology,Beijing, China, 100081
国际会议
中国微米纳米技术学会第14届学术年会、第3届国际年会暨第6届微米纳米技术“创新与产业化国际研讨与展览会(CSMNT2012 & ICMAN2012)
杭州
英文
1-4
2012-11-04(万方平台首次上网日期,不代表论文的发表时间)