Analysis of magnetic field for micro axial-flux electromagnetic generator
This paper reports on the magnetic field distribution and magnetic circuit calculating method of micro generator.A micro axial-flux electromagnetic generator is designed as size of Φ6mm×3mm.Traditional magnetic circuit analysis methods are used to retrieve the air-gap magnetic density on no-load micro generator in operation.FEA is done for the micro generator model using magnetic field numerical simulation software.The main parameters of no-load magnetic field and the waveform of induced EMF are obtained.Comparing the results obtained from the magnetic circuit analysis and numerical simulation,the error of air magnetic density is less than 2.54% and the error of the maximum value of induced EMF is less than 2.68%.The results suggest that magnetic circuit analysis methods can be used for magnetic field analysis of micro axial-flux electromagnetic generators,and be helpful to provide guidance for designs.
Micro-electromechanical system axial-flux electromagnetic generator magnetic field analysis magnetic circuit analysis numerical simulation
Tao Wu Ningjun Fan Yanxuan Wu
School of Mechatronic Engineering, Beijing Institute of Technology, Beijing, 100081, China
国际会议
中国微米纳米技术学会第14届学术年会、第3届国际年会暨第6届微米纳米技术“创新与产业化国际研讨与展览会(CSMNT2012 & ICMAN2012)
杭州
英文
1-5
2012-11-04(万方平台首次上网日期,不代表论文的发表时间)