Full-Scale Test on Domestic Sewage Treatment with Combination Aeration MBR Integration Equipment
Use combination aeration membrane bioreactor for urban sewage processing,when influent CODCr,BOD5,NH3-N concentration ranged:53.15~978.50 mg/L,28.23~431.55 mg/L,4.14~37.78 mg/L,when the hydraulic retention time (HRT) for 4 h,6 h,8 h,CODCr,BOD5 and NH3-N the average removal efficiencies were: above 90%,above 95%,above 90%,the best HRT for 6 h.Stable effluent quality,its range was CODCr: 3.5~30 mg/L;BOD5: below 5 mg/L;NH3-N: below 5 mg/L,effluent quality is better than The Reuse of Urban Recycling Water-Water Quality Standard for Urban Miscellaneous Water Consumption(GB/T 18920-2002).
combination aeration MBR domestic sewage integration HRT
Fengping Hu Cong Wan Wei Chen Pei Zhu
School of Civil Engineering and Architecture East China Jiaotong University Nanchang, China