Study of Numerical Simulation of Region CP System in a Large Pipeline Station
Newly built pipeline stations in China have widely used a cathodic protection system using flexible anodes and grid anodes.However,there may be some places in a pipeline station where the lack ofprotection may not be apparent because the data collected from several test posts cannot accurately represent the entire protection system in the station.After numerical simulation ofan ideal case without interferencefrom other metals,the results show uniform distribution in a flexible anodes system.But,if a grounding system exists in the model,interference will greatly influence the potential distribution.The result shows the potential distribution is no longer uniform and portions of pipe near the grounding system may not be protected.Due to the differences between characteristics of polarization in the grounding system and the pipeline,the addition of a sacrificial anodesystem is dvised.
Pipeline Station Region Cathodic Protection Numerical Simulation
Feng Zhang Wuxi Bi Hong Jin Bin Yu Zhiyuan Xue Weibin Wang
1Engineer, Petrochina Pipeline Research and Development Center; No.51, JinGuang Road, LangFang 06500 PhD, Petrochina Pipeline Research and Development Center; No.51, JinGuang Road, LangFang 065000 Engineer, Zhengzhou Oil and Gas Transportation Sub-Company; No. 45, Nongye East Road, Zhenzhou 45000 Vice Director, Petrochina Pipeline Research and Development Center; No.51, JinGuang Road, LangFang 0 Director, Petrochina Pipeline Research and Development Center; No.51, JinGuang Road, LangFang 065000