Cryogenic Treatment of 06Cr19Ni10 Austenitic Stainless Steel
The effect of cryogenic treatment on mechanical properties and wear resistance at room temperature of 06Cr19Ni10 austenitic stainless steel was studied in the present study.The cryogenic treatment process was carried out at -160℃ and different time in program-controlled cryogenic container.The results showed that,after cryogenic treatment,the room-temperature mechanical properties of the 06Cr19Ni10 steel remained stable without embrittlement,friction coefficient of the 06Cr19Ni10 steel decreased and the wear resistance improved after cryogenic treatment.When cryogenic treatment was treated at -160℃ for two hours and thirty minutes,the friction coefficient of the 06Cr19Ni10 steel was the smallest and wear resistance was the best.
Cryogenic treatment 06Cr19Ni10 austenitic stainless steel Mechanical properties Wear resistance
Hong Zhang Kaixuan Gu Jia Guo Xiaodai Xue Junjie Wang
Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Scien Graduate University of Chinese Academy of Sciences, 19 Yuquan Road, Shijingshan District,Beijing 100
国际会议
the Chinese Materials Congress 2012(2012年中国材料大会(CMC2012))
太原
英文
187-191
2012-07-13(万方平台首次上网日期,不代表论文的发表时间)