会议专题

Forward and Accuracy Verification for One-dimensional Transient Electromagnetic Method

  Forward of transient electromagnetic method is the basis of the theoretical study of transient electromagnetic prospecting,and the forward accuracy is the key factor of measured data processing and interpretation.Firstly,the calculation formula is derived for the vertical magnetic field of transient electromagnetic method with magnetic dipole source in the layered medium.Then,the vertical magnetic field component in the frequency domain is calculated by the Hankel transform.And then,the magnetic field component is transformed from the frequency domain to the time domain using the G-S transform.Finally,forward simulation is carried out for a typical layered model,and the accuracy of the forward simulation is verified.The simulation results show that the abnormal reaction of the transient electromagnetic method for the low resistance layer is obvious,and the interference of the low resistance shield layer is also evident.Also,the error analysis of the results shows that the forward results are reliable.This has an important role in guiding theoretical research and practical application.

Transient electromagnetic method forward Magnetic dipole source Hankel transform G-S transform Accuracy verification

Jianping Xiao Bo Liu Fan Wang Huichen Liang Cui Yu Shenglong He

School of Geosciences and Info-Physics, Central South University, Chang Sha, PRC

国际会议

第五届环境与工程地球物理国际会议(ICEEG 2012)

长沙

英文

139-143

2012-06-15(万方平台首次上网日期,不代表论文的发表时间)