Study on the susceptibility of welding cold cracking in SA543 steel
The hardenability and cold cracking susceptibility of welding joints of SA543 steel were studied. The carbon equivalent method was used to predict its hardenability. The cold cracking susceptibility of SA543 steel was investigated through the Y-groove Cracking test, the maximum hardness test of heataffected zone (HAZ), and the implant test for welding cold cracking. The results indicate SA543 steel has a high cold cracking susceptibility. A preheating temperature of no less than 100℃ for the butt welding of 80mm plate steel was recommended, which can improve the cold cracking susceptibility of the SA543 steel.
High strength low alloy steel Cold cracking susceptibility Carbon equivalent Implant test
Xuemei Luo Xuedong Chen Wanbo Dou Huaquan Bo
Hefei General Machinery Research Institute-National Engineering & Technical Research Center on Press Hefei General Machinery Research Institute - National Engineering & Technical Research Center on Pre
国际会议
2012 International Symposium on Structural Integrity 2012国际结构完整性学术研讨会 ISSI 2012
济南
英文
255-261
2012-10-31(万方平台首次上网日期,不代表论文的发表时间)