会议专题

A Novel Design of Fiber-Optic Sagnac Current Sensor

The principle of in-line Sagnac interferometer current sensor is presented. To simplify the modulation and eliminate the error caused by cross coupling, a new structure of current sensor is proposed here. Two end mirrored sensing fibers are winded around the conductor reversely. The modulating is much simpler and a simple analysis using Jones matrix has shown that this current sensor is feasible.

current sensor in-line Sagnac interferometer modulation Jones matrix

Hui Cao Nianbao Shi Jintao, Xu

State Key Laboratory of Transient Optics and Photonics Xian Institute of Optics and Precision Mechanics of CAS Xian, China

国际会议

2012 Fifth International Symposium on Computational Intelligence and Design 第五届计算智能与设计国际会议 ISCID 2012

杭州

英文

667-670