会议专题

Concentrated-leakage Detection by Emulation of Temperature Field

In order to detect the concentrated leakage passages (CLP) more effectively and precisely, the temperature field emulation method of irregularity dam including seepage and leakage is established based on numerical optimization of concentrated leakage passage detection with kinds of boundary conditions. In this model, the effect of lapse rate, radiation from sun and wind speed on temperature field is included. The flow states of underground water determined, the heat transfer characteristics presented and the coupled relation between seepage and temperature distribution constructed, the coupled equations between seepage and heat transfer are set up.

seepage dam safety temperature field emulation model inverse analysis

WANG Xin-jian LI Ri-yun CHEN Jian-sheng

North china Univ. of water conservancy and Electric power, Zhengzhou, China Geotechnical institute of civil department in hohai university, Nanjing, China

国际会议

2012 International Conference on Industiial Design and Mechanical Power(2012工业设计与机械动力国际会议 ICIDMP 2012)

黄山

英文

93-96

2012-07-10(万方平台首次上网日期,不代表论文的发表时间)