会议专题

On Quality Control Strategy in Last Stand of Tandem Cold Rolling Mill

In accordance with quality control strategy in last stand of a 1700mm tandem cold rolling mill, the control models of Monitor AGC with Smith predictor and tension controller were established, and decoupling arithmetic was given. Based on actual production problem, an optimizing strategy was developed to prevent tension from exceeding limits. The application shows that the system can quickly pull tension back to preset value, tension control precision can be controlled within ± 10% and the rolling line is more stable.

control strategy Cold rolling mill Monitor AGC Automatic tension control Decoupling control

ZHANG Xin ZHANG Dian-hua CHENG Ping-wen LI Xu SUN Jie

Stage Key Laboratory of Rolling and Automation, Northeastern University, Shenyang 110819, Liaoning, Special Steel Branch, Xinyu Iron and Steel Co., Ltd., Xinyu 338013, Jiangxi, China Stage Key Laboratory of Rolling and Automation, Northeastern University, Shenyang 110819, Liaoning,

国际会议

The 31st Chinese Control Conference(第三十一届中国控制会议)

合肥

英文

7562-7564

2012-07-01(万方平台首次上网日期,不代表论文的发表时间)