会议专题

Measurement of the Electric Initiating Device Temperature Using Infrared Microscopic Thermographer

The temperature of electric initiating device under constant current has the vital significance to the security and the firing performance of electrical explosive initiator. In this paper, the temperature of bridgewire and semiconductor bridge which were representative in electrical explosive devices (EED) was studied using the infrared microscopic thermographer. The curve of temperature with current change is obtained. The resluts indicate that the temperature increases with the current in the form of quadratic parabola and the temperature of semiconductor bridge rises slower than that of bridgewire. According to the experimental analysis, it is found the reason that the temperature of semiconductor bridge increases slower is attributed to the better heat conduction property due to the close-contact silicon between substrate and bonding pad.

electric initiating device infrared temperature measurement semiconductor bridge bridgewire

Wenchao Zhang Xiaowei Wang Bo Xu Dongping Zhang

School of Chemical Engineering, Nanjing University of Science & Technology, Nanjing 210094, China

国际会议

2012 International Conference on Advanced Materials Design and Machanics(2012先进材料设计与机械学国际会议 ICAMDM 2012)

厦门

英文

116-121

2012-06-05(万方平台首次上网日期,不代表论文的发表时间)