会议专题

Comparation of Calibration Methods for Bubbly Flow Video Image

Bubble flow video imaging device uses two high speed cameras to capture the bubble rising process in a transparent still sink. Tsai’s two step calibration method, Zhang Zhengyou calibration method, Camera Calibration Toolbox for Matlab are selected to do the calibration experiments on the high speed cameras. Each calibration method gives a different calibrated model. The accuracy of different model is compared. It’s proved that Zhang’s calibration method gives the most accurate model in this experiment. The fundamental of different calibration methods are given at the beginning. The calibrated model given by Zhang’s method is used to revise bubble parameters extracted from bubble flow images.

Bubble flow Video image Camera calibration

ZHANG Weida BIAN Yuchen DONG Feng

Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Auto Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Auto

国际会议

The 24th Chinese Control and Decision Conference (第24届中国控制与决策学术年会 2012 CCDC)

太原

英文

2614-2618

2012-05-23(万方平台首次上网日期,不代表论文的发表时间)