会议专题

Analysis on damping ratio of composite structure of pharmaceutical factory

In this paper, the damping ratio of Beijing Biological Pharmaceutical Factory, as a composite structure, is explored by using the MIDAS/GEN. Four 3D models, are established in order to consider the effects of material on structure; single damping ratio and the group of damping ratios is introduced respectively to calculate elastic interstory angular displacement and elastic-plastic interstory angular displacement. The results of both methods are compared so that the damping ratio of the composite structure can be estimated, which provides a foundation for similar structures in earthquake action calculation of damping ratio.

composite structure damping ratio elastic-plastic stage interstory angular displacement

Xiaobin Fan Honggang Lei

College of Architecture and Civil Engineering,Taiyuan University of Technology,Taiyuan, China College of Architecture and Civil Engineering, Taiyuan University of Technology,Taiyuan, China

国际会议

2012 International Conference on Electric Technology and Civil Engineering(2012 电子技术与土木工程国际会议 ICETCE 2012)

三峡

英文

1382-1385

2012-05-18(万方平台首次上网日期,不代表论文的发表时间)