会议专题

Analysis of Mechanical Behavior of Push-Out of Over-Thick Concrete Filled Steel Tube

Axial symmetry elasticity modeling of the concrete column which is constrained by over-thick steel tube and pushed out under axial compressive load is set up. The basic displacement method equations are derived. The distributions of displacement, stresses and strains of the concrete column are given. The experiment of push-out of over-thick concrete-filled steel tube (Over-Thick CFST) was carried out The curve of axial load-vertical displacement at the upper surface is measured. On the base of the test, the adhesive thin-layer between the concrete and the steel tube is introduced. The thickness of the adhesive thin-layer is approximated measured. The experimental results show that the shearing stress in the adhesive thin-layer is uniform along the height, which is coincide with the results obtained by the axial symmetry elasticity modeling of the concrete column which is constrained by over-thick steel tube and pushed out under axial compressive load. Therefore, the adhesive shearing stress between steel tube and concrete can be precisely measured by the experiment of push-out of Over-Thick CFST. The relation of shearing stress-shearing strain of the adhesive thin-layer can be determined.

put out test of over-thick CFST mechanical modeling adhesive thin-layer of steel tube/concrete adhesive shearing stress

Jiemin Liu Yazhen Sun Jinhe Gao

School of Science of Shenyang Jianzhu University Shenyang, China Dept. of Arch. and Civil Eng. of East China Ins. Of Tech.Nanchang, China

国际会议

2012 International Conference on Electric Technology and Civil Engineering(2012 电子技术与土木工程国际会议 ICETCE 2012)

三峡

英文

2971-2975

2012-05-18(万方平台首次上网日期,不代表论文的发表时间)