The Experimental Study on Extinguishing Aircraft Cabin Fire by Water Mist
The effect of flow coefficients, working pressures, nozzle layout and aircraft angle on extinguishing aircraft cabin fire by water mist were studied by experiment. The results show that the fire suppression effectiveness is increased with the increase of flow coefficient and working pressure; the diamond-shaped layout in sprinkler is better than square layout,and the aircraft angle of 30° is better than of 10°or 20°.
water mist fire-suppression flux exinguishment efficiency
Jian Chen Yanying Xu
School of Safety Engineering Shenyang Aerospace University Shenyang, China
国际会议
三峡
英文
3593-3596
2012-05-18(万方平台首次上网日期,不代表论文的发表时间)