Diagnosis of Energy Saving at Sewage Treatment Plants in China
The need to save energy at sewage treatment plants is a common issue in Japan and China. We applied a sewage treatment plant performance evaluation system to study energy-saving effects and effluent water quality by studying control settings values. The evaluation system is a simulator applicable to the sewage treatment plant process as a whole. It performs overall evaluation of effluent water quality and energy consumption by linking water treatment with sludge treatment. Diagnosis was made of two medium-size plants with a treatment capacity of 10,000 m3/day and one large treatment plant with a capacity of 150,000 m3/day. We studied control settings for MLSS, return sludge ratio, and reactor DO. The diagnosis indicated that power consumption could be reduced by 7 to 17%.
Sewage treatment plant electricity consumption effluent water quality diagnosis of energy saving
Toshiki FUKUSHIMA Isao SOMIYA Kohei INOUE Go NAKAGAWA
METAWATER Co., Ltd. (Shibaura Maekawa BIdg, 3-16-20 Shibaura, Minato-hi, Tokyo, Japan) Professor Emeritus, Kyoto University and Ryukoku University, Japan Fuji Electric Co., Ltd. Fuji Electric (China) Co., Ltd.
国际会议
深圳
英文
47-55
2012-04-13(万方平台首次上网日期,不代表论文的发表时间)