Thermoelectric Heat Pump Drying Temperature Control System on the Basis of 89C51
For the thermoelectric heat pump drying temperature control problems of nonlinear, considcrable inertia and long time delay, etc., design a kind of sectional type temperature control system which is based on fuzzy control. To validate temperature system control performance, the improvement based on the analysis of traditional fuzzy control technology, conducted fuzzy piecewise type control experiment for resistance furnace based on conventional fuzzy control and interpolation algorithm. The results indicate that, comparison with conventional fuzzy control, based on the location of the interpolation algorithm of control algorithm can realize multichannel and sectional type temperature control, which can effectively restrain the pure time delay of control system of the influence, and which has the advantages of small overshoot, high precision and good stability, etc.
Thermoelectric Heat Pump Drying Single Chip Microcomputer(SCM) Temperature Control
Peng Lei Xiao Ying
school of Electronic and Information Engineering Jinggangshan University jian, Jiangxi, China 343009
国际会议
杭州
英文
280-283
2012-03-23(万方平台首次上网日期,不代表论文的发表时间)