会议专题

Identification the low- frequency oscillation stakeout of power system by Wide-area Measurement System

With the rapid development of interconnected power grid, the phenomenon of power system low-frequency oscillation appears unavoidably. Then, the appearance of wide-area measurement system provided a supporting technology for better scout low-frequency oscillation system and better recognize the oscillation mode . In this paper, the existing oscillation mode identifying methods are analyzed from the viewpoint of calculation speed, criterion, calculation accuracy, etc. Mainly compared the applicability of two methods, Prony and ESPRIT . Based on the above research, a new idea of monitoring power system low frequency oscillation based on WAMS is put forward in this paper.

Keywords Wide-area Measurement System Low-frequency Oscillation Power System Mode Identify Prony Method Esprit Method

Yang Liu Qian Huang Dong Chen

School of Information Electrical Engineering China University of Mining and Technology Xuzhou, China, 221008

国际会议

4th International Conference on Measuring Technology and Mechatronics Automation(第四届检测技术与机电自动化国际会议 ICMTMA 2012)

三亚

英文

594-601