Review of Upward Positive and Bipolar Lightning Flashes at the Gaisberg Tower

First instrumentation for lightning measurements at the Gaisberg Tower (GBT) has been installed in 1998.During the 10-years period from 2000 – 2009 a total of 652 lightning events have been recorded.Vast majority of the lightning to the GBT was upward initiated and only one record is a candidate for a downward flash when the recorded current waveform is used for discrimination between upward and downward lightning.3% (21/652) of the flashes were bipolar and about the same number of 4% (26/652) were positive.73% of positive and 63% of bipolar lightning was triggered by the GBT during cold season in Austria.

Gerhard Diendorfer Helin Zhou Hannes Pichler Rajeev Thottappillil

Austrian Electrotechnical Assoziation (OVE),Dept.ALDISKahlenberger Str.2A,1190 Vienna,Austria Division of Electromagnetic EngineeringKTH Royal Institute of TechnologyTeknikringen 33 SE-100 44 St Division of Electromagnetic Engineering KTH Royal Institute of Technology Teknikringen 33 SE-100 44

国际会议

第七届亚太防雷国际会议

成都

英文

1-5

2011-11-01(万方平台首次上网日期,不代表论文的发表时间)