Unconnected Upward Leaders Observed in Guangzhou during 2009-2010

More than ten unconnected upward positive leaders initiated from high structures in response to natural downwardmoving negative leaders are analyzed.These leaders are observed by using high-speed cameras with sampling rates at the order of 104 fps (frames per second).The propagation velocity, channel width of the unconnected upward leader and the distances between it and strike point are presented.The results can deepen our understanding of the lightning attachment process.

Weitao Lu Luwen Chen Yang Zhang Ying Ma Qiyuan Yin Shaodong Chen Yijun Zhang

Laboratory of Lightning Physics and Protection Engineering,Chinese Academy of Meteorological Science Lightning Protection Center of Guangdong Province,Guangzhou,510080,Guangdong Province,P.R.China

国际会议

第七届亚太防雷国际会议

成都

英文

1-5

2011-11-01(万方平台首次上网日期,不代表论文的发表时间)