Test Procedures and Signal Misinterpretation for Electrostatic Gassolids Flowmeters

This paper discusses the current methods used to test electrostatic pulverised fuel meters in a laboratory environment and the precautions to be taken to ensure that ‘meaningful’ results are obtained. In particular, the effect of particle attrition is discussed and results presented from a laboratory test facility at the University of Teesside.

Pulverised Fuel Meter Testing Particle Attrition

J Coulthard R Cheng J Zhang R P Keech

Teesside University, Middlesbrough. Tees Valley TS1 3BA. U.K ABB Ltd, Stonehouse, Gloucestershire GL10 3TA. U.K.

国际会议

The 9th International Coference on Measurement and Control of Granular Materials(第九届国际粉体检测与控制学术会议)(MCGM 2011)

上海

英文

1-5

2011-10-27(万方平台首次上网日期,不代表论文的发表时间)