Optimization Design of Capacitance Sensor with Helical Shaped Surface Plates
Optimized capacitance sensor with helical shaped surface plates has an obvious advantage of smaller homogeneous error which helps to make the measurement result insensitive to phase distribution and flow changes. The angle of rotation is one of the most important structural parameters to the sensor optimization design. The effect of rotation angle of the helical surface plate to the performance of the sensor with different diameters was studied in this paper. Results showed that the best rotation angle of the helical surface plate was different for different sizes of sensor. 360 degree rotation angle is the best to obtain the smallest homogeneous error when the diameter is greater than 32mm, however, 180 degree is the best when the pipe diameter is less than 31mm, ,
Capacitance sensors Phase concentration Helical surface plate Plate rotation angle.
Yutao Wang Jinfeng Yuan Gang Yang Yunfen Qiao
School of Information Science and Engineering, Northeastern University, ChinaNo.11, Lane 3, Wenhua Road, Heping District, Shenyang, 110004, China
国际会议
上海
英文
92-95
2011-10-27(万方平台首次上网日期,不代表论文的发表时间)