Comparison and Analysis of Different Standards for Determining Dust Resistivity
Accurate measurement of dust resistivity is important practically for electrostatic prevention and design of electrostatic precipitators. The test result of dust resistivity depends on the standard used. There are three standards widely used for determination of dust resistivity: IEC 1241-2-2, BS 5958-1 and ASME PTC28 4.05. Experimental devices are designed and constructed according to these standards. The schematics of test principles and circuits of different standards are introduced. Experimental results show that dust resistivity values determined by different standards are quite different, and in some cases the difference is even in 1~2 orders of magnitude. The test results according to IEC standard are the highest, while the results using ASME standard are the lowest. The methods given by IEC standard and BS standard are normally used in electrostatic prevention, while method given by ASME standard is applied to the design of electrostatic precipitators. It is necessary to choose the appropriate standard according to the application of dust resistivity.
Dust Resistivity Electrostatic Prevention Electrostatic Precipitators Measurements.
Xin Jin Shengjun Zhong Weiye Li
School of Materials and Metallurgy, Northeastern University, China School of Information Science and Engineering, Northeastern University, China No.11, Lane 3, Wenhua
国际会议
上海
英文
110-113