Research on Stator Winding Inter Turn Short-circuit Faults of Aeronautical Fault-tolerant Machine Based on Maxwell 2D

Stator winding inter turn short-circuit fault is one of the most common internal faults of fault-tolerant machine, which can disconnect the fault phases and keep operating correctly in the event of a failure. Stator winding short-circuit fault model is established through analysis. Based on finite element method, the high-power density fault-tolerant machine internal magnetic field simulation and analysis is implemented using Maxwell2D and induced voltage frequency spectrum is analyzed by FFT method. The characteristics of stator winding short-circuit faults are summarized, which lay a solid foundation for fault-tolerant machine earlier faults prediction and winding switching.

High-power density Fault-tolerant machine Inter turn short-circuit Finite element method Maxwell2D FFT.

ZHANG Ming ZHANG Yiming TONG Jiangtao

Beijing University Of Technology.Beijing, 100124,P.R.CHINA