Isolation Performance Evaluation of Compressor Vibration Isolating Systems Based on LMS Test. Lab Signature
In order to reduce vibration and noise of the compressor used in small and medium-sized refrigeration unit, this paper designs different vibration isolating systems and carries out experiment of isolation performance evaluation based on LMS Test. Lab Signature software. The comparison results of four different vibration isolating systems show that the peak values of vibration velocity response in each system mainly appear at 25Hz, 50Hz, 75Hz and lOOHz, and the maximum velocity does not exceed 22mm/s which is less than the maximum allowed by the national standard11. And the Vibration Level Difference(VLD)is taken as evaluation criteria for isolating vibration, that of single-layer vibration isolating system is within 10-20dB, and that of double-layer vibration isolating system is within 2035dB. Furthermore with the increase of middle-mass, the VLD has a clear upward trend.
Isolation Performance Evaluation Compressor Vibration Isolating System LMS TestLab Signature Vibration Level Difference
Zhang Li Chen Hao Gong Yanjue Wu Hong Zhang Shuo
school of Material & Mechanical Engineering,Beijing Technology and Business University, Beijing, China
国际会议
合肥
英文
1220-1225
2011-09-23(万方平台首次上网日期,不代表论文的发表时间)