会议专题

Based on Taguchi Analysis for High Power LED Liquid-Cooling System Design

The main result of this study is to propose a liquidcooling system for high power LED heat dissipation treatment. By using thermal dissipation mechanism and based on ANSYS CFX numerical analysis of change the parameters of cold plat. We will get the optimal heat dissipation structure. The experimental results show that the Taguchi method of thermal mechanisms in this study of the four control factors affecting the order: k value of thermal compound > fan power > liquid type > pump flow rate, and to identify the best combination of factor levels. When the heat source is 90 W, the best factor of the experimental cooling system thermal resistance is 0.563K/W.

High Power LED Cooling Liquid Systems Taguchi Method Control Factors

San-Shan Hung Hsing-Cheng Chang Jhih-Wei Huang

Department of Automatic Control Engineering, Feng-Chia University Taichung, 40724 Taiwan

国际会议

2011 3nd International Conference on Mechanical and Electronics Engineering(2011年第三届机械与电子工程国际会议 ICMEE2011)

合肥

英文

3967-3971

2011-09-23(万方平台首次上网日期,不代表论文的发表时间)