会议专题

A PXI based Operating-Strategy-Configurable ERT for Gas-Water Horizontal Flow Regime Identification

Electrical Resistance Tomography (ERT) technique has great prospective in industrial measurement and monitoring with merits of non-intrusive, non-radiant, visualization and etc. However, the application of this technique is restricted by its real-time performance. In this paper, the scheme of the Opetating-Strategy-Configurable ERT system based on PXI module instruments has been proposed. The Operating-Strategy-Configurable ERT System can work in different working Strategies including 16electrodes mode, 8-electrodes mode and 4-clectrodes for different flow regime, 16-electrodcs mode is used for imaging, 8-electrodes and 4-elcctrodes mode for regime identification and monitoring The result shows that, when the ERT system is working in dual-plane mode, the sampling speed of each plane is 625 frames/s at 16-electrodes mode, 1562frames/s at 8electrodes mode, and 3125 frames/s at 4-electrodes mode. It has improved the system real-time performance. The characteristic value which is extracted by the wavelet from the measured data of each cross section shows that the system has a good capacity of identification flow regimes.

Electrical Resistance Tomography PXI Operating-Strategy-Configurablc Flow Regime

CAO Yang DONG Feng TAN Chao

Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Automation Tianjin University, Tianjin 300072, China

国际会议

The 7th International Symposium on Measurement Techniques for Multiphase Flows(第七届国际多相流测试技术会议)

天津

英文

182-188

2011-09-17(万方平台首次上网日期,不代表论文的发表时间)