Effect of Particle Distribution on Electrostatic Tomography System

Particle is charged due to frictional contact and collisions between particles and pipe wall. Electrostatic tomography technology (EST) is used to monitor the traveling particle charge. However the electric field distribution in the electrostatic sensor arrays is simultaneously affected by both the particle permittivity distribution and particle charge. In the paper, the effect of the different particle flow regimes on EST is investigated numerically and experimentally. Results indicated the particle distribution affected the induced charge on the electrostatic sensor array. But the effect relates to the relationship between the charge distribution and the particle distribution. Furthermore, a fusion of dual modality tomography system consisting of a capacitance sensor and electrostatic sensor arrays is used to investigate the relationship between the particle distribution and charge distribution in a gravity conveying rig. Results showed that the higher particle concentration has higher charge distribution in the gravity conveying rig. Additionally, the measurement of the mass flow rate by EST was investigated.

Electrostatic Tomography charge distribution Dual modality tomography system Particle distribution

Gao heming Xu chuanlong Fu Feifei Wang Shimin

Thermal Energy Engineering Research Institute, Southeast University, Nanjing 210096, P R China

国际会议

The 7th International Symposium on Measurement Techniques for Multiphase Flows(第七届国际多相流测试技术会议)

天津

英文

269-276