Microwave Doppler System for Multiphase Flow Measurement
This paper describes the use of microwave Doppler sensors for measuring the flow velocity of vertical gas-water, oil-water and gas-oil-water flows. The microwave Doppler system has a single dielectricfilled antenna flush mounted on the wall of a metallic pipe, and delivers liquid velocity data with accuracy within ±10% of reading over a wide range of gasvolume fractions.
microwavc Doppler velocity fraction multiphase flow
Cheng-gang Xie Zhipeng Wu
Schlumberger Cambridge Research Ltd, High Cross, Madingley Road, Cambridge CB3 OEL, UK The University of Manchester, School of Electrical & Electronic Engineering, Manchester Ml 3 9PL, UK
国际会议
The 7th International Symposium on Measurement Techniques for Multiphase Flows(第七届国际多相流测试技术会议)
天津
英文
319-326
2011-09-17(万方平台首次上网日期,不代表论文的发表时间)