会议专题

Evaluation of Sulfide Corrosion Conditions in Pulverized Coal Fired Thermal Power Plant Boilers

Due to cutbacks in operational costs,many pulverized coal fired thermal power plant boilers have recently been operating under conditions of in-furnace reduction atmosphere enhancement.As a result,stronger in-furnace reduction atmospheres have led to sulfide corrosion.CRIEPI has conducted a study to clarify correlations between boiler operation conditions and sulfide corrosion,and to develop effective sulfide corrosion couritermeasures.This report therefore describes experimental and theoretical results of research into evaluation techniques for a sulfide corrosion environment,along with actual applied results of evaluation techniques for a sulfide corrosion environment using an in-furnace of an active boiler.

Sulfide corrosion NOx Reduction atmosphere Boiler tube Pulverized coal

M.Morinaga S.Najima N.Wakabayashi H.Shirai

Energy Engineering Research Laboratory,Central Research Institute of Electric Power Industry (CRIEPI Materials Science Research Laboratory,Central Research Institute of Electric Power Industry (CRIEPI)

国际会议

The 7th International Symposium on Coal Combustion(第七届国际煤燃烧学术会议)

哈尔滨

英文

736-741

2011-07-19(万方平台首次上网日期,不代表论文的发表时间)