Fine Frequency Grid Calibration and the Experiment for NVNA Based on Squared Crystal

This paper studies on the low phase resolution of the phase calibration of a mixer-based two-port coaxial Nonlinear Vector Network Analyzer (NVNA), especially the absolute calibration techniques. A new method of fine frequency grid calibration based on squared crystal detector has been made. The narrowband calibration principle of the way to calibrate the NVNA by using the squared crystal detector is deduced, and the calibration process is given. Simulation results of ADS and the experiment prove the effectiveness of the proposed method, and its phase calibration resolution achieves 100KHz.

Squared crystal detector Nonlinear Vector Network Analyzer Phase absolute calibration Fine frequency grid calibration

Xu Qinghua Lin Maoliu

Division of Time and Frequency Metrology National Institute of Metrology P. R. China Beijing, China School of Electronics and Information Engineering Harbin Institute of Technology Harbin, China

国际会议

2012 5th Global Symposium on Millimeter-Waves(2012年第五届全球毫米波会议 GSMM 2012)

哈尔滨

英文

241-244

2012-05-27(万方平台首次上网日期,不代表论文的发表时间)