会议专题

Simulation of Three-Phase Three-Wire Shunt APF With One-Cycle Control Under Double-Direction Compensation by PSCAD/EMTDC

In the light of the DC component existing in active power filter (APF) based on traditional one-cycle control strategy, one-cycle control under double-direction compensation control strategy is presented. One-cycle control under double-direction compensation shunt APF is designed, which is used in three-phase three-wire system. APF with resistive inductive load is simulated by PSCAD/EMTDC. Simulation results show that the proposed control method not only can eliminate the harmonic and reactive current effectively but also can eliminate the DC component. This control method provides theoretical and experimental guide for the application of APF.

active power filter (APF) one-cycle control PSCAD/EMTDC

Liu Xujiang Li Wenjuan Cheng Huaiying Zhang Wei Gao Hanying

School of Electrical and Electronic Engineering Harbin University of Science &Technology Harbin, China

国际会议

2012 International Conference on Measurement,Information and Control(2012测量、信息与控制国际会议 ICMIC2012)

哈尔滨

英文

543-547

2012-05-18(万方平台首次上网日期,不代表论文的发表时间)