会议专题

The Implementation of a Portable 3D Analyzer Using Infrared Technique

This study is major to establish a portable NDT imaging system of infrared to provide the 2D CT as well as 3D CT images. The developed system is using the transmission of infrared to observe the structure of test phantoms; To match up the accurate angles feature on stepping motor to complete the continuous imaging on phantom with different angles, and then reconstruct the serial images to 2D CT images and 3D CT images by using the back projection and superposition principle. The results show that the method we proposed in phantoms verification is feasible, but it is unsatisfied to measure the human fingers. It means that the proposed back projection algorithm in human fingers reconstruction still needs to be improved.

Angiography Infrared 2D and 3D CT image

Pei-Jarn Chen Chia-Hong Yeng Yi-Chun Du Chia-Hao Chang Cheng liu

Department of Electrical Engineering,Southern Taiwan University, Tainan, Taiwan Department of Electrical Engineering, Southern Taiwan University, Tainan, Taiwan Department of Electrical Engineering, Southern Taiwan University, Tainan, Taiwan Institute of Biomed Division of Plastic Surgery, Chi-Mei Medical Center, Tainan, Taiwan

国际会议

2011 3rd International Conference on Computer Engineering and Applications(2011第三届计算机工程与应用国际会议 ICCEA2011)

海口

英文

400-404

2011-07-15(万方平台首次上网日期,不代表论文的发表时间)