Effect of pre-oxidized CuO layer in joining between polyethylene terephalate (PET) and copper (Cu) by using pulsed Nd:YAG laser
In the present study, effect of preoxidized (PO) CuO layer in the joining between polyethylene terephalate (PET) and copper (Cu) by using pulsed Nd:YAG laser was investigated The experimental result for PET/PO Cu (with pre-oxidized layer) and PET/Cu (without pre-oxidized layer) were presented in this paper. The results showed the preoxidation surface improved the welding efficiency. The welded area and tensile shear failure load (TSFL) of PET/PO Cu joint were increased when pre-oxidized layer was introduced. This indicates that high heat was absorbed during laser irradiation of PET/PO-Cu joint compare to PET/Cu joint. On the other hand, the fracture surface of PET/PO-Cu showed the presence of Cu and Cu oxide particles in the PET side. While in case of PET/Cu, no occurrence of Cu particles can be observed. The presence of Cu oxide particles and Cu particles were believed may increase PET/PO Cu joint shear force. From the cross-sectional observation of PET/PO Cu joint interface, it was found that an oxide layer in the laser irradiation area was removed and PET seemed to have intimate contact with Cu surface.
dissimilar welding polyethylene terephalate copper laser welding surface oxidation
Farazila Yusof Yoshiharu Mutoh Yukio Miyashita
Department of Mechanical Engineering,Nagaoka University of Technology,940-2188 Nagaoka,Japan Departm Department of System Safety,Nagaoka University of Technology,940-2188 Nagaoka,Japan
国际会议
2010 International Conference on Material and Manufacturing Technology(2010材料与制造技术国际会议 ICMMT2010)
重庆
英文
714-718
2010-09-17(万方平台首次上网日期,不代表论文的发表时间)