会议专题

Pre-treatment of high-strength acid dye wastewater with internal electrolysis-Fenton process

It was studied that the performance of the internal electrolysis-Fenton process in pre-treating of the high-strength refractory acid dye wastewater. The sequencing comparative experiments were carried out and it was determined that the internal electrolysis-Fenton process was superior to the traditional one in terms of treatment effect. Optimal conditions were attained by experimental conditions changing. The results show that under optimal conditions pH=2, the volume ratio of Fe/GAC is 1 and the reaction time is 30 min. The dosage of H2O2 is 4‰ by continuously dosing, its pH is 3 and the reaction time 30 min. the COD removal rate could be more than 75% and the BOD5/COD ratio could be increased from 0.08 to 0.46. This process showed highly efficient in organic removal and biodegradability improving in pre-treating high-strength dye wastewater.

internal electrolysis-Fenton process acid dye wastewater pre-treatment biodegradibility BOD5/COD

Zhanli Chen Jian Zhan Zhenzhong Liu

School of Civil Engineering and ArchitectureNanchang UniversityNanchang, China School of Civil Engineering and Architecture Nanchang University Nanchang, China

国际会议

2012 International Conference on Intelligent System Design and Engineering Applications(2012年智能系统设计与工程应用国际会议 ISDEA 2012)

三亚

英文

472-476

2012-01-06(万方平台首次上网日期,不代表论文的发表时间)