会议专题

Continuous Element Determination of Barium-Calcium Based on Single Sample of Ferroalloy Series

To achieve bath analysis of Barium and Calcium in ferroalloy, potassium chromate is used to precipitate Ba2+ and Ca2+ & Ba2+ is tested in filtrate/filter residue with EDTA and Fe2+ after acidification, respectively. Short-cycle analysis, single testing sample used and effectively shielding of hetero-ions are the main advantages of this method. Under situation where immediate testing is needed without any specialized analytical equipments, this method will be practically effectual.

Bath analysis Alkaline-Earth Metal Determination Barium-Calcium-Silicon Ferroalloy

Li Xi-Ming

Department of Polymer Science and Engineering, University of Science and Technology of China, Hefei, Anhui 230026, P.R.China

国际会议

2011 International Conference on Advanced Materials and Engineering Materials(2011先进材料与工程材料国际会议 ICAMEM 2011)

沈阳

英文

381-386

2011-11-22(万方平台首次上网日期,不代表论文的发表时间)