Design of 12bit 100MHz Sample and Hold Circuit for Pipeline ADC
In this paper, design methods of Sample and Hold (S/H) circuit are discussed and gm/id method in OTA (Operational Transconductance Amplifiers) design is applied. Based upon the discussion, circuit design develops from the signal modeling, which would make circuit design concisely and easily. This work is elaborated in details by TSMC 0.18μm CMOS process. Folding telescope structure is applied for main OTA design, with two gain-boost OPAMPs, in order to achieve high gain and high GBW. In this paper, both main OTA and gain-boost OPAMP are design in gm/id method, and obtain circuit parameters from interpolated data simulated by H-Spice and MATLAB. Post-simulation and chip measurement results show that the S/H circuit performs well.
gm/id method Gain-boost folding telescope OTA Slew rate Flip-around S/H
Zheng Hao Fan Xiangning Sun Yutao
Institute of RF- & OE-ICs, School of Information Science and Engineering Southeast University Institute of RF- & OE-ICs, School of Information Science and EngineeringSoutheast University
国际会议
南京
英文
1-5
2011-11-09(万方平台首次上网日期,不代表论文的发表时间)