会议专题

The novel heating method for the sample of spectral emissivity measurement

In order to eliminate the temperature difference between center measurement points and surface temperature of the material samples with low thermal conductivity, this paper introduces a new hot airflow double-sided heating method for sample, and describes its principle, application, and the impact of the existing and novel methods on the measurement results of spectral emissivity. Also, we analyze and compare the results of two different samples obtained with these two heating methods. The new method for material samples with low thermal conductivity has outstanding advantages and potential applications.

Spectral Emissivity Surface Temperature Measurement Hot Airflow Double-sided Heating Method

Li Xing Zundong Yuan Minchen Guo Dong Wei Lizhi cai Boping Wang

North China Electric Power University, No.2, beinonglu, changping District, Beijing, P.R.China Natio National Institute of Metrology P.R.China, No. 18, Bei San Huan Dong Lu,Chaoyang District, Beijing, North China Electric Power University, No.2, beinonglu, changping District, Beijing, P.R.China Fujian Metrology Institute, 9Ping Dong Road, FuZhou, FuJian, P.R.China

国际会议

2011 International Conference on Machanical Engineering,Materials and Energy(2011年机械工程、材料与能源国际会议 ICMEME 2011)

大连

英文

951-957

2011-10-19(万方平台首次上网日期,不代表论文的发表时间)