会议专题

Preliminary Numerical Simulation of Pulsatile Flow in Aortic Arch with Left Subciavian Artery

In this paper, the preliminary numerical simulation of pulsatile flow in aortic arch with left subciavian artery was conducted by the software ANSYS based on the finite element method. In order to facilitate a preliminary study, the geometric model of aortic arch with left subciavian artery was simplified as a bent pipe of 30mm in diameter with a curved-shape branch pipe. The curved-shape branch vessel is associated with the human physiological pulsatile flow in this study to address the questions about blood flow. An average blood flow rate is established according to the physiological pulsatile flow condition. The pulsatile flow in a 3-D curved-shape branch vessel is simulated numerically with the flow function, and then make general postprocessor, the distributions of velocity, pressure and wall shear on different time of the cardiac cycle are obtained.

aortic arch finite element method pulsatile flow numerical simulation

Fujun Wang Lei Zhang Lu Wang Yuling Li

The Key Lab of Textile Science & Technology, Ministry of Education, Donghua University, Shanghai, P R China

国际会议

2011 4th International Conference on Biomedical Engineering and Informatics(第四届生物医学工程与信息学国际会议 BMEI 2011)

上海

英文

1163-1165

2011-10-15(万方平台首次上网日期,不代表论文的发表时间)