Study on Collection Efficiency of 2-layered Electrostatic Filters with Different Gaps
In this paper, we study to analyze the effect of the gap between two filters on particle collection effiency of electrostatic filter system which is applied to subway cabin. Two sheets of electrostatic filter with different gap size (2 mm, 5 mm, 8 mm) and no gap are used and compared. The particle collection efficiency of four cases is different. In the case of filter with 8 mm gap has the highest particle collection efficiency. The result shows that filter with gap has better particle collection efficiency than filters with no gap and gap size between two filters is significant factor to affect the particle collection efficiency of electrostatic filter system.
Electrostatic filter Efficiency improvement Diffierent gap
Soohyun Ha Jong-Bum Kim Soon-Bark Kwon Seok Namgoong Kwanhyun Cho Taesung Kim
SKKU Advanced Institute of Nanotechnology,Sungkyunkwan Univercity,300 ChunChundong Jangan-gu,Suwon-s Railroad Environment Research Department,Korea Railroad Research Institute,Woram-dong,Uiwang-si,Gyeo R&D System Team,Seungchang Airtek,Naegachoen-ri Wongok-myeon,Anseong-si,Gyeonggi-do,456-811,Korea R&D center,Seoulmetro,Dongjak-dong,Dongjak-gu,Seoul,137-712,Korea SKKU Advanced Institute of Nanotechnology,Sungkyunkwan Univercity,300 ChunChundong Jangan-gu,Suwon-s