ASYMMETRIC NUCLEIC ACID SEQUENCE-BASED AMPLIFICATION (ASYMMETRIC-NASBA): A DIFFERENT METHOD OF CONVENTIONAL NASBA
Nucleic acid sequence-based amplification (NASBA) is a homogeneous, isothermal, in vitro amplification resulting in the amplification of target sequences more than 109-fold within 120 min1. The main amplicons of NASBA are RNA, and currently all the detection method are designed for RNA. In this paper, asymmetric NASBA with unequal concentrations of T7 promotor primer and reverse transcription primer was proposed. By optimizing the ratio of two primers and the concentration of dNPTs and NTPs, the amount of single-stranded cDNA in the amplicons from asymmetric NASBA was found increased 12 times more through the real-time detection of molecular beacon specific to cDNA of interest
NASBY asymmetric
Jia Huning Chen Zhiyao Wu Haiping Ye Hui Zhou Guohua
Department of Analytical Chemistry , China Pharmaceutical University, Nanjing 210009,China Huadong Research Institute for Medicine and Biotechnics, Nanjing 210002, China Medical School, Nanji Huadong Research Institute for Medicine and Biotechnics, Nanjing 210002, China School of life science and technology, China Pharmaceutical University, Nanjing 210009, China