Study on Dynamic Simulation of 4-bundle Ice-coated Conductor Galloping Based on 3-D Model

Galloping of power transmission lines is a low frequency self-oscillation with large amplitude. The aerodynamic effect on each sub-conductor of 4-bundle conductor is different due to wake-flow-influence. In order to explore the reasons leading to galloping, a 3-D model for power transmission line is built. A two-node quadratic beam element in 3-D and a structure mass element are applied to establish the finite element model of iced 4-bundle conductor in ANSYS software. Then dynamic transient response calculations are made on this model. According to the results, difference in vibration of sub-conductors and frequency coupling of torsional and transverse vibration can be confirmed. The simulation results illustrate the wake-flow-influence effect and the coupled motions effect on galloping of 4-bundle conductor.

Galloping 4-bundle Conductor 3-D Model Dynamic Simulation

Shi Jing Wu Zeng Lei Zhang Zhen Hao Liu Ji Cai Hu

School of Power and Mechanical Engineering, Wuhan University, Wuhan, 430072, P. R. China

国际会议

2011 International Conference on Vibration,Structural Engineering and Measurement(2011年振动、结构工程与测量国际会议 ICVSEM 2011)

上海

英文

474-477

2011-10-21(万方平台首次上网日期,不代表论文的发表时间)