Experimental Study on Strengthening the Structure of Tower of Overhead Transmission Line
Serious damage and collapse of steel towers were easily induced by the ice disaster, the wind disaster and so on. After the disaster, to ensure the overhead transmission line working safely, it is necessary to strengthen the structure of the damaged tower perpetually, but there are few strengthening methods for the tower assembled by angle-shaped members at present. If an identical angle-shaped member is connected on the side of the existing angle-shaped member through bolts, the mechanical performance of the damaged tower can be improved effectively. In this paper several methods for strengthening the angle-shaped tower is proposed, and the mechanical behavior of the strengthened member of the tower is discussed experimentally, and some design suggestions for strengthening the towers are given.
overhead transmission line steel tower angle-shaped member strengthened member
Xuewu Liu Kaiquan Xia Yan Gao
China Electric Power Research Institute, Beijing, 100192, China
国际会议
上海
英文
1069-1072
2011-10-21(万方平台首次上网日期,不代表论文的发表时间)