Bi-camera Ranger-finder and Error Analyze Based on Binocular Parallax
The traditional facilities that used to find range are mostly based on laser or ultrasonic. Now, based on binocular parallax of human eyes, we advance a method used to get the distance by measuring the offset on image panel. On this foundation, we also analyze the error in forward. The academic analysis indicate that the measurement would be impacted severely by transverse offset and angle-measuring offset, in contrast, much slightly by lengthways offset. When we put this facility into practice, this facility can suffice practical demand completely if we select the space between bi-camera and the focus of facility rationally.
Human eyes imaging Range find Single pixel error
Zi Chen WANG Ming DAI Jing HUANG Yong Yang WANG Xiao Lu CHEN Yu Jun GAO
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Science,Changchun, Jil Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Science,Changchun, Jil Changchun University of science and technology, Changchun, Jilin, China
国际会议
上海
英文
1843-1846
2011-10-21(万方平台首次上网日期,不代表论文的发表时间)