会议专题

Influences of Temperature of Vapour-Condenser and Pressure in the Vacuum Chamber on the Cooling Rate during Vacuum Cooling

The temperature of vapour-condenser below 0℃ and the final pres-sure in the vacuum chamber below 0.61kPa during vacuum cooling were ex-perimentally analysed in this paper. The temperature of vapour-condenser, 2t,-35℃,-39t and-71℃, and the final pressure in the vacuum chamber, 0.3kPa, 0.4kPa, 0.5kPa and 0.61kPa, were chosen. The experimental results showed that the cooling rate varies with the temperature of vapour-condenser and the final pressure in the vacuum chamber. Water vapour becomes the frost on the surface of vapour-condenser when the initial temperature of vapour-condenser is below 0t, which is helpful to trap water vapour for vapour-condenser. In addition, the formation mechanism of frost at the surface of vapour-condenser was analysed in this paper. The cooling time for vacuum cooling can be reduced when the final pressure in the vacuum chamber varied from 0.4kPa to 0.61kPa. However, the surface temperature of cooked meat occurred freezing when the final pressure in the vacuum chamber was 0.3kPa. Therefore, in order to reduce the cooling time and avoid freezing, the temperature of vapour-condenser should be set around-30℃~℃ and the final pressure in the vacuum chamber can be defined at from 0.4kPa to 0.61kPa.

Temperature Pressure Vapour-condenser Vacuum cooling

Tingxiang Jin Gailian Li Chunxia Hu

School of Mechanical & Electricity engineering, Zhengzhou University of Light Industry,5 Dong Feng Road, Zhengzhou 450002, Henan Province, P. R. China

国际会议

The 4th IFIP International on Computer and Computing Technologies in Agriculture and the 4th Symposium on Development of Rural Information(第四届国际计算机及计算机技术在农业中的应用研讨会暨第四届中国农业信息化发展论坛 CCTA 2010)

南昌

英文

41-52

2010-10-22(万方平台首次上网日期,不代表论文的发表时间)