Design and Fabrication of Cu-TSV Free-standing Specimen for Uniaxial Micro-tensile Test
A novel test sample with a micro scale free-standing specimen of Cu-TSV used for uniaxial micro-tensile test is presented in this paper. Design of a deformation-buffer reticular supporting frame of the test sample effectively reduces the deformation of Cu-TSV thin film during clamping operatioa The stress resulting from electrodepositon process is minimized by fabricating Cu-TSV thin film on surface-treated titanium seed layer. The process of titanium seed layer avoids alkali corrosion and simplifies fabrication procedure compared with that of the traditional Cr/Cu seed layer. Both finite-element method (FEM) simulation and experimental results indicates the advantages of this new design. The test sample fabricated by the optimized process well coordinates with our micro-tensile system. The Youngs modulus and the ultimate tensile strength of tested Cu-TSV thin film measured by our micro-tensile system are 25.4~32.9GPa and 574~764MPa, respectively.
Junyi Li Hong Wang Huiying Wang Zhengjie Zhang Ping Cheng Guifu Ding
National Key Laboratory of Science and Technology on Nano/Micro Fabrication Technology Shanghai Jiao Tong University, Shanghai, China
国际会议
2011 International Symposium on Advanced Packaging Materials(2011年先进电子封装材料国际会议APM)
厦门
英文
318-321
2011-10-25(万方平台首次上网日期,不代表论文的发表时间)