会议专题

A calibration method based on fusing multiple calibrators for UWB-VAR system using stepped frequency

The system calibration is an important factor for the detecting effect of UWB-VAR (Ultra Wide Band Virtual Aperture Radar) which can penetrate the earth to explore the weak scattering target flush buried in the shallow seam. The regular system calibration method developed for high frequency narrow band radar is based on one single calibrator, which is not applicable to the UWB-VAR system owning to its ultra bandwidth and inconsistency of multi-channel. After the research on the system errors and the electromagnetism of both calibrators and landmines, a new method based on the fusion of multi-calibrators and multi-band is introduced in this paper. This new method would not only calibrate the system errors efficiently, but enhance the performance of imaging. Finally the real data has proved that such a method can be effective.

VAR System calibration Multi-calibrator Multi-band fusion

P.Y. Wang Z.M. Zhou Q. Song T. Jin

School of Electronic Science and EngineeringNational University of Defense TechnologyChangsha, Hunan School of Electronic Science and Engineering National University of Defense Technology Changsha, Hun

国际会议

2011 IEEE CIE International Conference on Radar(2011年IEEE国际雷达会议RADAR 2011)

成都

英文

308-311

2011-10-24(万方平台首次上网日期,不代表论文的发表时间)