Study on Torque Ripple Reduction of Direct Torque Control System Based on DSVM
With the limitation of number of the voltage vectors in Voltage Source Inverter, the reasonable switching table of the traditional direct torque control is not able to be established and the torque ripple is large. A new method based on discrete space vector modulation is proposed to improve this problem in this paper, in which the number of voltage vectors is increased, the value and phase of voltage vectors are more continuous. Also, the different switching tables are established according to the different speed so that the large torque ripple is avoided. The experimental results show this method reduces the torque ripple and current ripple significantly.
direct torque control discrete space vector modulation torque ripple Asynchronous motor
Bo Fan Guanghui Shi Yixin Yin Cunfa Fu Juwei Zhang
CITIC Heavy Industries Co. Ltd, Luoyang, China CITIC Heavy Industries Co. Ltd, Luoyang, China School CITIC Heavy Industries Co. Ltd, Luoyang, China School of Information Engineering, University of Science and technology Bejing, Bejing, China
国际会议
哈尔滨
英文
771-774
2011-08-12(万方平台首次上网日期,不代表论文的发表时间)