A Modified Robust CFAR Detector
A modified variability index (MVI) CFAR detector is presented. The MVI is a combination of the cell averaging (CA), grcatest-of (GO), and modified trimmed mean (MTM). The analytic expression of its threshold multiplier factor TMTM is also derived. Under SwerUing II assumption, the MVI is evaluated and compared with the CA,OS,VI and OSVI (order statistic VI) through Monte-Carlo simulation in various environments. In homogeneous background and clutter edge environment, the MVI keeps the good performance of VI. In multiple targets background, the MVI performs robustly, which is similar to OS. In addition, the MVI shortens the sample sorting time of the OS and the OSVI.
Radar Automatic detection Constant false alarm rate (CFAR) variability index (VI) Nonhomogeneous background
Congan Xu You He Qingqing Yao Tao Jian
Naval Aeronautical and Astronautical University, Yantai Shandong, 264001, China Ocean University of China, Qingdao Shandong, 266100, China
国际会议
哈尔滨
英文
4439-4442
2011-08-12(万方平台首次上网日期,不代表论文的发表时间)