Identification of Load on a Point-of-Load (PoL) Voltage Converter: An Automated Algorithm and Its Implementation

In this paper, a method has been presented for determining the type and value of load attached across a BMR-450 Point-of-Load (PoL). To do this, a measurement circuit is designed to measure the inductor current inside the BMR-450. The measured data is then taken to the LabView software by means of a data acquisition system. A user friendly interface is designed in the software, and an algorithm for load identification has been implemented and presented.

BMR-450 Point-of-Load Load Identification

Raisul Haque Ajoy Kumar Dey Susmita Saha Shibani Ghosh Avijit Saha

Dept. of Electrical Engineering, Signal Processing Blekinge Tekniska Hogskola Karlskrona, Sweden Dept. of Electrical and Electronic Engineering Bangladesh University of Engineering and Technology D

国际会议

2011 International Conference on Communication and Electronics Information(ICCEI 2011)(2011年通信和电子信息国际会议)

海口

英文

118-121